- Products
- Market Solutions
- Newsroom
- Tools & Resources
- About Nexans New Zealand
- Search
- Contact us
- Compare
- Sign in
CU VERSOLEX 1x 300 GNYE
CU VERSOLEX 1x 300 GNYE
VERSOLEX
CU VERSOLEX 1x 300 GNYE
Read more- Nexans ref. : BDSE91HE001HTNA
- Country ref. : 8341
- EAN : 9319215514778
Description
Description
Standards
-
ProductAS/NZS 1125; AS/NZS 3808; AS/NZS 5000.1
- 0.6/1kV cables,
- Flexible X-HF-90 (XLPE) insulated
- TPE sheathed to AS/NZS5000.1 (Power),
- Copper conductors (Class 5), 90°C.
- Submersible up to 500m
- Used for fixed application.
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Conductor material
Copper
Type of conductor
Circula, Flexible, Class 5
Colour
Green / yellow
Insulation
X-HF-90
Conductor flexibility
Class 5
Conductor shape
Circular
Outer sheath
TPE
With Green/Yellow core
No
With smaller neutral conductor
No
Dimensional characteristics
Dimensional characteristics
Conductor cross-section
300 mm²
Maximum diameter of wires
0.51 mm
Nominal overall diameter
32.3 mm
Approximate weight
301.0 kg/100m
Cable length
- m
Neutral conductor section (when smaller)
- mm²
Number of cores
1
Electrical characteristics
Electrical characteristics
Conductor AC resistance at 50 Hz
- Ohm/km
Inductive reactance at 50Hz - flat touching
- Ohm/km
Inductive reactance at 50Hz - trefoil
- Ohm/km
Insulation resistance at 20°C
- MOhm.km
Rated Voltage Uo/U (Um)
0,6/1 kV
Max. DC resistance of the conductor at 20°C
0.064 Ohm/km
Mechanical characteristics
Mechanical characteristics
Cable flexibility
Flexible for fixed application
Maximum Pulling Tension
15 kN
Mechanical resistance to impacts
Very good
Usage characteristics
Usage characteristics
U.V resistance
Very good
Minimum Bending Radius during installation
9 (xD)
Bending factor when installed
4 (xD)
Maximum operating temperature
90 °C
Minimum operating temperature
0 °C
Resources
Resources
Documentation
Nexans Versolex approval certificate
pdf — 2.3 MB
Current carrying capacities single phase (in Amps) - Single Core CU Versolex 90°C
Copper conductor - Circular Flexible stranded conductor Insulation X-HF-90 - Max. Conductor Temperature 90⁰CConductor cross-section | |||||||
---|---|---|---|---|---|---|---|
mm² | Cu | Cu | Cu | Cu | Cu | Cu | Cu |
300.0 | 776 | 653 | 0 | 761 | 586 | 586 | 0 |
Unenclosed spaced from surface |
Unenclosed touching |
Enclosed conduit in air |
Buried direct |
Buried in multi-way duct |
Buried in single-way duct |
Cable surrounded by thermal insulation, unenclosed |
Current carrying capacities three phase (in Amps) - Single Core CU Versolex 90°C
Copper conductor - Circular Flexible stranded conductor Insulation X-HF-90 Max. Conductor Temperature 90⁰CConductor cross-section | |||||||
---|---|---|---|---|---|---|---|
mm² | Cu | Cu | Cu | Cu | Cu | Cu | Cu |
300.0 | 701 | 650 | 504 | 630 | 513 | 513 | 0 |
Unenclosed spaced from surface |
Unenclosed touching |
Enclosed conduit in air |
Buried direct |
Buried in multi-way duct |
Buried in single-way duct |
Cable surrounded by thermal insulation, unenclosed |
Our websites
Select your country to find our products and solutions
-
Africa
- Africa
- Ghana
- Ivory Coast
- Morocco
- North West Africa
- Americas
- Asia
- Europe
- Oceania