- Products
- Market Solutions
- Newsroom
- Tools & Resources
- About Nexans New Zealand
- Search
- Contact us
- Compare
- Sign in
CU ENVIRO RHE-1-FLEX 4X 16+6E OG
CU ENVIRO RHE-1-FLEX 4X 16+6E OG
ENVIROLEX
Multicore flexible copper conductor, 0.6/1kV X-90 insulated, HFS-90-TP sheathed to AS/NZS 5000.1
Read more- Nexans ref. : HTHX02HF004OMEM
- Country ref. : 8926
- EAN : 9319215467777
Description
Description
Standards
-
ProductAS/NZS 5000.1
-
TestIEC 60332-1; IEC 60754-1
ENVIROLEX® flexible multicore cable is part of the Nexans Fire Safety Offer. As a Low Fire Hazard (LFH) range, ENVIROLEX® is PVC-free, made with flame retardant compound and reduces toxic smoke emissions in the event of fire, allowing time for safe evacuation.
- Class 5 flexible conductor
- 0.6/1kV cables,
- Flexible, X-90 insulated
- HFS-90-TP sheathed to AS/NZS 5000.1 (Power)
- 90°C continuous
- Submersible to 500m
- Used for fixed application
Characteristics
Characteristics
Construction characteristics
Construction characteristics
With Green/Yellow core
Yes
Conductor material
Copper
Type of conductor
Stranded copper
Insulation
X-HF-90
Outer sheath
HFS-90-TP
Colour
Orange
Conductor flexibility
Class 2
Conductor shape
Circular
Insulation colour
Red, White, Blue, Black, Green/Yellow
With smaller neutral conductor
No
Dimensional characteristics
Dimensional characteristics
Conductor cross-section
16 mm²
Number of cores
4
Approximate weight
89.4 kg/100m
Maximum diameter of wires
0.41 mm
Neutral conductor section (when smaller)
- mm²
Nominal insulation thickness
0.7 mm
Nominal outer sheath thickness
1.8 mm
Nominal overall diameter
22.8 mm
Number of earth cores
1
Electrical characteristics
Electrical characteristics
Conductor AC resistance at 50 Hz
1.64 Ohm/km
Inductive reactance at 50Hz - flat touching
- Ohm/km
Inductive reactance at 50Hz - trefoil
- Ohm/km
Insulation resistance at 20°C
490 MOhm.km
Max. DC resistance of the conductor at 20°C
1.21 Ohm/km
Rated Voltage Uo/U (Um)
0,6/1 kV
Mechanical characteristics
Mechanical characteristics
Cable flexibility
Flexible for fixed application
Mechanical resistance to impacts
Very good
Usage characteristics
Usage characteristics
Fire safety
-
U.V resistance
Yes
Maximum operating temperature
90 °C
Minimum operating temperature
-25 °C
Resources
Resources
Current carrying capacity table - Envirolex-Multicore (Three Phase)
Flexible Copper Conductor Circular stranded Insulation X-HF-90 Max. Conductor Temperature 90⁰CConductor cross-section | ||||||
---|---|---|---|---|---|---|
mm² | Cu | Cu | Cu | Cu | Cu | Cu |
16.0 | 96 | 89 | 45 | 85 | 118 | 85 |
Air spaced from surface, unenclosed |
Air touching, unenclosed |
Cable surrounded by thermal insulation, unenclosed |
Air enclosed |
Buried direct |
Buried in single-way duct |
Selling & delivery Information
Nexans Fire Safety Offer ENVIROLEX® Low Fire Hazard Cables PVC-free Red List Free and Declare Labelled Green Star Flexible conductor
Our websites
Select your country to find our products and solutions
-
Africa
- Africa
- Ghana
- Ivory Coast
- Morocco
- North West Africa
- Americas
- Asia
- Europe
- Oceania