- Products
- Market Solutions
- Newsroom
- Tools & Resources
- About Nexans New Zealand
- Search
- Contact us
- Compare
- Sign in
AAC Aerial Conductors (Covered)
AAC Aerial Conductors (Covered)
Aluminium conductor, PVC cover. Made to AS/NZS 5000.1
Read moreNamu CVD 7_2.11
Nexans ref. BAAB53AA001CXAA - Country ref. 4373
- Packaging: Cut to length (m)
- Conductor cross-section: 24.5 mm²
- Stranding (No./mm): 7/2.11
- Insulation sheath thickness: 1.2 mm
- Nominal overall diameter: 8.9 mm
- Approximate weight: 0.12 kg/m
- Minimum breaking load: 4.07 kN
Ladybird CVD 7_2.79
Nexans ref. - Country ref. 2511
- Conductor cross-section: 42.8 mm²
- Stranding (No./mm): 7/2.79
- Insulation sheath thickness: 1.4 mm
- Nominal overall diameter: 11.4 mm
- Approximate weight: 0.2 kg/m
- Minimum breaking load: 6.92 kN
Kutu CVD 7_3.00
Nexans ref. BAAB32AA001CXAA - Country ref. 3416
- Packaging: Cut to length (m)
- Conductor cross-section: 49.5 mm²
- Stranding (No./mm): 7/3.00
- Insulation sheath thickness: 1.4 mm
- Nominal overall diameter: 12.0 mm
- Approximate weight: 0.22 kg/m
- Minimum breaking load: 7.98 kN
Fly CVD 7_3.40
Nexans ref. BAAB57AA001CXAA - Country ref. 4421
- Packaging: Cut to length (m)
- Conductor cross-section: 63.6 mm²
- Stranding (No./mm): 7/3.40
- Insulation sheath thickness: 1.4 mm
- Nominal overall diameter: 13.2 mm
- Approximate weight: 0.28 kg/m
- Minimum breaking load: 9.98 kN
Rango CVD 7_3.66
Nexans ref. BAAB59AA001CXAA - Country ref. 9751
- Packaging: Cut to length (m)
- Conductor cross-section: 73.6 mm²
- Stranding (No./mm): 7/3.66
- Insulation sheath thickness: 1.4 mm
- Nominal overall diameter: 14.0 mm
- Approximate weight: 0.31 kg/m
- Minimum breaking load: 11.2 kN
Wasp CVD 7_4.39
Nexans ref. BAAB61AA001CXAA - Country ref. 5605
- Packaging: Cut to length (m)
- Conductor cross-section: 106 mm²
- Stranding (No./mm): 7/4.39
- Insulation sheath thickness: 1.6 mm
- Nominal overall diameter: 16.6 mm
- Approximate weight: 0.44 kg/m
- Minimum breaking load: 16.1 kN
Beetle CVD 19_2.67
Nexans ref. BAAB66AA001CXAA - Country ref. 5912
- Conductor cross-section: 106 mm²
- Stranding (No./mm): 19/2.67
- Insulation sheath thickness: 1.6 mm
- Nominal overall diameter: 16.8 mm
- Approximate weight: 0.44 kg/m
- Minimum breaking load: 17.2 kN
Weke CVD 19_3.35
Nexans ref. BAAB36AA001CXAA - Country ref. 5032
- Packaging: Cut to length (m)
- Conductor cross-section: 122 mm²
- Stranding (No./mm): 7/4.72
- Insulation sheath thickness: 1.8 mm
- Nominal overall diameter: 18.0 mm
- Approximate weight: 0.52 kg/m
- Minimum breaking load: 18.6 kN
Weta CVD 19_3.35
Nexans ref. BAAB67AA001CXAA - Country ref. 2395
- Packaging: Cut to length (m)
- Conductor cross-section: 167 mm²
- Stranding (No./mm): 19/3.35
- Insulation sheath thickness: 1.8 mm
- Nominal overall diameter: 20.7 mm
- Approximate weight: 0.65 kg/m
- Minimum breaking load: 26.2 kN
Description
Description
Standards
-
ProductAS 1531; AS/NZS 5000.1
Application
AAC - All Aluminium Conductor
AAC aerial conductor is made of aluminium 1350 strand. It is designed for short & medium spans with a high conductivity.
The PVC covering contains a high level of carbon black for UV resistance. The covering is not considered as an electrical insulation. This type of aerial cable is designed for harsh environments such as coastal areas; the conductor is protected by the PVC covering to reduce the risk of aluminium corrosion.
Note
- Coefficient of linear expansion 23.0 x 10-6/°C.
a. Modulus of elasticity 65 GPa
Current ratings are based on an ambient temperature of 30°C, a maximum conductor temperature of 75°C, rural weathered, summer noon and intensity of solar radiation 1000 W/m².
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Electrical characteristics
Electrical characteristics
Usage characteristics
Usage characteristics
Our websites
Select your country to find our products and solutions
-
Africa
- Africa
- Ghana
- Ivory Coast
- Morocco
- North West Africa
- Americas
- Asia
- Europe
- Oceania