Al Aerial Bundled cables (ABC)
Al Aerial Bundled cables (ABC)
Aluminium conductor, XLPE insulation. Made to ASNZS 3560.1.
Read moreAL AERIAL ABC: LV 2X 25^
Nexans ref. XDAB17AA002AALL - Country ref. 6166
- Packaging: Cut to length (m)
- Pilot wires: None
- Number of cores: 2
- Conductor cross-section: 25 mm²
- Conductor diameter: 5.99 mm
- Insulation sheath thickness: 1.3 mm
- Nominal overall diameter: 18.4 mm
- Approximate weight: 0.2 kg/m
- Minimum breaking load: 7 kN
AL AERIAL ABC: LV 2X 35^
Nexans ref. XDAB18AA002AALL - Country ref. 1566
- Packaging: Cut to length (m)
- Pilot wires: None
- Number of cores: 2
- Conductor cross-section: 35 mm²
- Conductor diameter: 6.9 mm
- Insulation sheath thickness: 1.3 mm
- Nominal overall diameter: 20.6 mm
- Approximate weight: 0.26 kg/m
- Minimum breaking load: 9.8 kN
AL AERIAL ABC: LV 2X 50^
Nexans ref. XDAB19AA002AALL - Country ref. 2259
- Packaging: Cut to length (m)
- Pilot wires: None
- Number of cores: 2
- Conductor cross-section: 50 mm²
- Conductor diameter: 8.05 mm
- Insulation sheath thickness: 1.5 mm
- Nominal overall diameter: 23.8 mm
- Approximate weight: 0.35 kg/m
- Minimum breaking load: 14 kN
AL AERIAL ABC: LV 2X 95^
Nexans ref. XDAB22AA002AALL - Country ref. 6877
- Packaging: Cut to length (m)
- Pilot wires: None
- Number of cores: 2
- Conductor cross-section: 95 mm²
- Conductor diameter: 11.4 mm
- Insulation sheath thickness: 1.7 mm
- Nominal overall diameter: 31.8 mm
- Approximate weight: 0.68 kg/m
- Minimum breaking load: 26.6 kN
AL AERIAL ABC: LV 3X 35^
Nexans ref. XDAB18AA003AALM - Country ref. 1991
- Pilot wires: None
- Number of cores: 3
- Conductor cross-section: 35 mm²
- Conductor diameter: 6.9 mm
- Insulation sheath thickness: 1.3 mm
- Nominal overall diameter: 22.2 mm
- Approximate weight: 0.39 kg/m
- Minimum breaking load: 14.7 kN
AL AERIAL ABC: LV 4X 35^+1P 16^
Nexans ref. XDAB18AAP04AALP - Country ref. 3635
- Packaging: Cut to length (m)
- Pilot wires: 16 mm²
- Number of cores: 4
- Conductor cross-section: 35 mm²
- Conductor diameter: 6.9 mm
- Insulation sheath thickness: 1.3 mm
- Nominal overall diameter: 25.4 mm
- Approximate weight: 0.61 kg/m
- Minimum breaking load: - kN
AL AERIAL ABC: LV 4X 70^+1P 16^
Nexans ref. XDAB20AAP04AALP - Country ref. 4520
- Pilot wires: 16 mm²
- Number of cores: 4
- Conductor cross-section: 70 mm²
- Conductor diameter: 8.05 mm
- Insulation sheath thickness: 1.5 mm
- Nominal overall diameter: 33.3 mm
- Approximate weight: 1.05 kg/m
- Minimum breaking load: - kN
AL AERIAL ABC: LV 4X 95^+1P 16^
Nexans ref. XDAD22AAP04AALP - Country ref. 5742
- Pilot wires: 16 mm²
- Number of cores: 4
- Conductor cross-section: 95 mm²
- Conductor diameter: 11.4 mm
- Insulation sheath thickness: 1.7 mm
- Nominal overall diameter: 39.1 mm
- Approximate weight: 1.44 kg/m
- Minimum breaking load: - kN
AL AERIAL ABC: LV 4X 95^+2P 16^
Nexans ref. XDAB22AAL04AALP - Country ref. 4940
- Packaging: Cut to length (m)
- Pilot wires: 16mm² (x2)
- Number of cores: 4
- Conductor cross-section: 95 mm²
- Conductor diameter: 11.4 mm
- Insulation sheath thickness: 1.7 mm
- Nominal overall diameter: 39.1 mm
- Approximate weight: 1.5 kg/m
- Minimum breaking load: - kN
AL AERIAL ABC: LV 4X 25^
Nexans ref. XDAB17AA004AALP - Country ref. 1152
- Pilot wires: None
- Number of cores: 4
- Conductor cross-section: 25 mm²
- Conductor diameter: 5.99 mm
- Insulation sheath thickness: 1.3 mm
- Nominal overall diameter: 22.2 mm
- Approximate weight: 0.4 kg/m
- Minimum breaking load: 14 kN
AL AERIAL ABC: LV 4X 35^
Nexans ref. XDAB18AA004AALP - Country ref. 4001
- Packaging: Cut to length (m)
- Pilot wires: None
- Number of cores: 4
- Conductor cross-section: 35 mm²
- Conductor diameter: 6.9 mm
- Insulation sheath thickness: 1.3 mm
- Nominal overall diameter: 24.9 mm
- Approximate weight: 0.52 kg/m
- Minimum breaking load: 19.6 kN
AL AERIAL ABC: LV 4X 50^
Nexans ref. XDAB19AA004AALP - Country ref. 5517
- Packaging: Cut to length (m)
- Pilot wires: None
- Number of cores: 4
- Conductor cross-section: 50 mm²
- Conductor diameter: 8.05 mm
- Insulation sheath thickness: 1.5 mm
- Nominal overall diameter: 28.7 mm
- Approximate weight: 0.7 kg/m
- Minimum breaking load: 28 kN
AL AERIAL ABC: LV 4X 70^
Nexans ref. XDAB20AA004AALP - Country ref. 9523
- Pilot wires: None
- Number of cores: 4
- Conductor cross-section: 70 mm²
- Conductor diameter: 9.69 mm
- Insulation sheath thickness: 1.5 mm
- Nominal overall diameter: 32.8 mm
- Approximate weight: 0.96 kg/m
- Minimum breaking load: 39.2 kN
AL AERIAL ABC: LV 4X 95^
Nexans ref. XDAB22AA004AALP - Country ref. 8256
- Packaging: Cut to length (m)
- Pilot wires: None
- Number of cores: 4
- Conductor cross-section: 95 mm²
- Conductor diameter: 11.4 mm
- Insulation sheath thickness: 1.7 mm
- Nominal overall diameter: 38.4 mm
- Approximate weight: 1.35 kg/m
- Minimum breaking load: 53.2 kN
Description
Description
Standards
-
ProductAS/NZS 3560.1
Application
Aerial Bundled Cable is designed for residential and rural areas for reducing the bushfire hazards. The XLPE covering contains a high level of carbon black for UV resistance. It is designed for where reliability, safety and low installation cost are required, but it is only for short spans due to increased weight.
Note
- Coefficient of linear expansion 23.0 x 10-6/°C.
a. Modulus of elasticity 59 GPa up to and including 50mm² and 56 GPa for conductors above 50mm².
Current ratings are based on an ambient remperature of 30ºC, a maximum conductor temperature of 80ºC, wind speed of 1 m/s and intensity of solar radiation 1000 w/m².
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Electrical characteristics
Electrical characteristics
Usage characteristics
Usage characteristics
Our websites
Select your country to find our products and solutions
-
Africa
- Africa
- Ghana
- Ivory Coast
- Morocco
- North West Africa
- Americas
- Asia
- Europe
- Oceania